Protege Half DIN Rail
2 Reader Expander
PRT-HRDM-DIN
The Protege Half DIN Rail 2 Door Reader Expander delivers up to 4 reader inputs and 2 locking device outputs, in a compact two-tier half DIN rail design.
With 8 inputs that can be used for extended monitoring functionality, and 6 open collector outputs available for management of controllable devices, the Reader Expander features extensive hardware advancements that support flexible security and access control, alarm monitoring and building automation.
- 2 doors (4 readers)
- 8 multi purpose inputs
- 2 Form C relay outputs
- 6 low current outputs
Features
Specifications
| Ordering Information | |
| PRT-HRDM2-DIN | Protege Half DIN Rail 2 Door Reader Expander |
| Power Supply | |
| DC Input Voltage | 11-14VDC |
| DC Output Voltage | 10.83-14.0VDC 0.7A (typical) electronic shutdown at 1.1A |
| (DC IN Pass Through) | Reader 1&2 10.45-13.85VDC pass through share 0.7A (typical) electronic shutdown at 1.1A |
| Operating Current | 80mA (Normal Standby) |
| Total Combined Current* | 1.6A (max) |
| Low Voltage Cutout | 8.7VDC |
| Low Voltage Restore | 10.5VDC |
| Communication | |
| RS-485 | Module network |
| Offline Operation | |
| Offline Access Modes | All Users, First 10 Users plus 150 Card Cache, No Users |
| Readers | |
| Reader Configurations | 2 reader ports that can be independently configured for either Wiegand (up to 1024 bits configurable) or RS-485, allowing connection of up to 4 readers providing entry/exit control for two doors ** |
| RS-485 reader port connections support configuration for OSDP protocol | |
| Outputs | |
| Lock Outputs | 2 Form C relay outputs, 7A N.O/N.C. at 30 VAC/DC resistive/inductive |
| PGM Outputs | 6 (50mA max) open collector |
| Inputs | |
| Zone Inputs | 8 high security monitored inputs (10ms to 1hr input speed programmable) |
| Trouble Inputs | 16 |
| Dimensions | |
| Dimensions (L x W x H) | 78 x 90 x 60mm (3.07 x 3.54 x 2.36″) |
| Net Weight | 210g (7.4oz) |
| Gross Weight | 270g (9.5oz) |
| Operating Conditions | |
| Operating Temperature | UL/ULC 0° to 49°C (32° to 120°F) : EU EN -10° to 55°C (14° to 131°F) |
| Storage Temperature | -10°- 85°C (14° – 185°F) |
| Humidity | 0%-93% non condensing, indoor use only (relative humidity) |
| Mean Time Between Failures (MTBF) | 622,997 hours (calculated using RFD 2000 (UTE C 80-810) Standard) |
* The Total Combined Current refers to the current that will be drawn from the external power supply to supply the expander and any devices connected to its outputs. The Auxiliary outputs are directly connected via thermal resettable fuses to the N+ N- input terminals, and the maximum current is governed by the trip level of these fuses.
** Each reader port supports either Wiegand or RS-485 reader operation, but not both at the same time. If combining reader technologies, they must be connected on separate ports.
The ICT implementation of OSDP conforms to a subset of the OSDP functionality. For specifications and reader configuration, refer to AN-254 Configuring OSDP Readers, available from the Integrated Control Technology website.